What daily checks matter most before starting pile driving work?
Start with the basics the VANROCK specification makes visible: verify the carrier matches the model class, confirm hydraulic settings, and check the hammer and extension boom weights against your planned set-up. This attachment family is built for easy installation and operation, but model matching still matters.
- Confirm excavator class matches the hammer model range
- Confirm setting pressure is 300 bar
- Confirm oil flow matches the model’s required l/min range
- Check the jaw opening requirement of 65 mm
It is also sensible to verify the selected working range for the model before the job starts: 7 / 7.5 m on VR-SH 15 Tilt up to 11.5 / 12.5 m on VR-SH 40 Tilt. The VANROCK specification does not list a separate wear-parts inspection schedule.
Questions & Answers · VANROCK Group